banner

elastomeric joint sealant

Hogar

elastomeric joint sealant

  • Matching Grout to the Specifics of Your Crack
    Dec 31, 2025
    Let’s clear the air on a painful, expensive myth: there is no universal "fix-all" grout. That recurring, weeping crack in your basement or warehouse isn't being stubborn; it's likely being treated with the wrong medicine. Pouring a fast-expanding foam into a stable, structural fissure is as counterproductive as using a slow-cure epoxy on a gushing leak. The true key to a permanent seal isn't just injection—it's precise material selection. Your concrete communicates its problems. A crack’s width, moisture level, and movement tell a clear story. The most common mistake is reacting only to the symptom (water) without diagnosing the cause (crack type). Decoding the Crack's Language: The "Weeping" Hairline Crack (< 1mm): This is often a slow capillary leak. The surface is damp, but no active flow exists. Wrong Approach: A rigid, high-viscosity epoxy. It won't penetrate deeply enough. Right Weapon: Low-Viscosity, Penetrating Epoxy or Acrylic. Why: These materials have the consistency of thin syrup, wicking deep into the microscopic pore structure. They cure to form a barrier at the root of the problem. Cure time is slower (4-12 hours), allowing for complete saturation. The "Gushing" Active Leak (1mm - 10mm): You see water flow. This is an emergency. Wrong Approach: Any material that requires a dry substrate or cures slowly. It will wash away. Right Weapon: Hydrophilic (Water-Activated) Polyurethane. Why: This grout uses the water as a chemical trigger. Upon contact, it foams and expands rapidly (15-30x), forming a flexible, watertight plug within 60-90 seconds. It chases the water to its source. The "Moving" Seasonal Crack: This crack opens and closes with temperature or settlement. It's dry sometimes, wet others. Wrong Approach: Rigid cementitious or standard epoxy grout. It will crack again within a season. Right Weapon: Flexible, Elastomeric Polyurethane. Why: Engineered to stretch and compress (up to 300% elongation), it accommodates the movement that caused the crack in the first place. It acts like a rubber band within the concrete, maintaining the seal through freeze-thaw cycles and settling. The Pro’s First Step: Before any injection, the crack is cleaned and a series of small ports are installed. The choice of grout—penetrating, hydrophilic, or elastomeric—determines everything that follows. It’s the difference between a temporary patch and a decades-long solution.
    LEER MÁS

Dejar un mensaje

Dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.
entregar

Hogar

Productos

whatsApp

contacto